Home Up Contact Us About Us Specifications News Careers


VAPORTIGHT COAT®-SG2 & SG3 surface applied vapor emission barriers
(for commercial use only)

 Link

Product

Description

Warranty

VAPORTIGHT COAT®-
SG2

HEAVY DUTY vapor barrier and oil barrier
up to
25 lb/24 hr*1000
ft2
(up to 5 g/h/m2
bullet10-year material
bullet10-yr material & labor, inc. flooring system available

VAPORTIGHT COAT®-
SG2/VO

HEAVY DUTY vapor barrier and oil barrier coating for VERTICAL & OVERHEAD SURFACES
bullet10-year material
bullet10-yr material & labor, inc. flooring system available

VAPORTIGHT COAT®-
SG3

NON-BROADCAST vapor barrier
up to
25 lb/24 hr*1000 ft2
(up to 3 g/h/m2
bullet10-year material
bullet10-yr material & labor, inc. flooring system available

VAPORTIGHT COAT®-
SG3/FC

FAST CURING, NON-BROADCAST  vapor barrier coating  
bullet10-year material
bullet10-yr material & labor, inc. flooring system available
 
Product Selection Chart
MVER Application Rates

 

Easy Application

Step 1: Surface prep

Step 2: Mix SG material
Click for mixing details

Step 3: Pour + Spread out
     
Step 4: Scrub in Step 5: Roll back Step 6: Sand
Step 7: Flooring applied next day
 

PRODUCT SELECTION CHART

 

SG2

SG3

Physical properties

HEAVY DUTY

Non-Broadcast

Material

2-component epoxy

2-component epoxy

Color

White or light grey

Clear

Mixing Ratio

100:12

100:50

Density at 68ºF

15.49 lb/gal  (1.86 kg/L)

9.08 lb/gal  (1.09 kg/L)

VOC content, mixed

0.5 lb/gal (55 g/L)

0 lb/gal (0 g/L)

Volume solids

97%

100%

Reduces vapor emission up to

95%

97%

Recoat time – minimum / maximum

None

12  hr / 5 days

Curing temperature – minimum

46ºF (8ºC)

50ºF (10ºC)

 

Application characteristics:

 

 

Moisture vapor emission barrier

YES

YES

MVER reduction to 3 lb (0.6 g) or less

YES

YES

1-coat application

YES

YES

Flooring system installed next day

YES

YES

Sealing oil contaminated slabs

YES

NO

2ndary containment barrier

YES

NO

Applied to new concrete

YES (min. 5 days old)

YES (min. 5 days old)

Applied to moist or dry concrete

YES

YES

Application to slabs

YES

YES

Application to walls

YES

YES

Requires full broadcast of sand

YES

NO

High alkalinity barrier (pH 13 - 14)

YES

YES

Suitable for MMA's (Vinylesters/Polyesters)

YES

NO

 

SG2 SG3

Application Rates for MVER

No. of Coats

Yield
1 coat application

Yield
1 coat application

lb/24hr * 1000ft2

g/h/m2

 

ft2/gal

kg/m2

ft2/gal

kg/m2

Up to 15

0 – 3.0

1

95

0.80

110

0.40

15 – 20

3.0 – 4.0

1

95

0.80

90

0.50

20 – 25

4.0 – 5.0

1

75

1.00

70

0.67

New concrete (min. 5 days old)

1

95

0.80

85

0.53

 

Warranty

 

 

MVER reduction to 3lb or less

YES

YES

10-year material warranty

YES

YES

10-year material & labor (full system) to licensed applicators, approved on a per project basis

YES

YES

 

MVER = Moisture Vapor Emission Rate

 

Picture showing
  penetration of SG2
  into substrate

SG2 12036-12.jpg (161899 bytes)

 Click on picture to enlarge

 

Back Up Next                                         
Copyright © 2007 AQUAFIN, Inc.     Last modified: June 25, 2008     Phone: USA (410) 392-2300   info@aquafin.net